Model NO.: 3x120MM2
Wire Core Material: Bare Copper Wire
Certification: ISO
Model: YJLV22
Brand: Jytop
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Certificate: Ce/ ISO9001
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
Model NO.: 3x120MM2
Wire Core Material: Bare Copper Wire
Certification: ISO
Model: YJLV22
Brand: Jytop
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Certificate: Ce/ ISO9001
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
21/35kv 3X90mm2 Copper XLPE insualted PVC sheathed Power Cable CU/XLPE/PVC(or PE) Power Cable
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
2. Operating Characteristics
Rated voltage U0/U(Um): 21/35(40.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
4. Manufacturing Standards IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
Main technical data of 21/35KV, three cores, Copper conductor, XLPE insulated, and PVC or PE sheath cable ;
CABLE CONSTRUCTION: 21/35KV CU/XLPE/PVC or PE
 Size |
Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20 0 C (Ω/km) |
3x50mm 2 | 9.3 | 0.10 | 3.3 | 74.7 | 0.387 |
3x70mm 2 | 9.3 | 0.10 | 3.4 | 78.6 | 0.268 |
3x95mm 2 | 9.3 | 0.10 | 3.5 | 82.3 | 0.193 |
3x120mm 2 | 9.3 | 0.10 | 3.6 | 85.6 | 0.153 |
3x150mm 2 | 9.3 | 0.10 | 3.7 | 89.3 | 0.124 |
3x185mm 2 | 9.3 | 0.10 | 3.8 | 93.0 | 0.0991 |
3x240mm 2 | 9.3 | 0.10 | 4.0 | 98.7 | 0.0754 |
3x300mm 2 | 9.3 | 0.10 | 4.2 | 103.4 | 0.0601 |
3x400mm 2 | 9.3 | 0.10 | 4.4 | 110.9 | 0.0470 |
 21/35kv 3X90mm2 Copper XLPE insualted PVC sheathed Power CableÂ
CU/XLPE/PVC(or PE) Power Cable
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
2. Operating Characteristics
Rated voltage U0/U(Um): 21/35(40.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
4. Manufacturing Standards IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
Main technical data of 21/35KV, three cores, Copper conductor, XLPE insulated, and PVC or PE sheath cable ;
CABLE CONSTRUCTION: 21/35KV CU/XLPE/PVC or PE
 Size |
Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20 0 C (Ω/km) |
3x50mm 2 | 9.3 | 0.10 | 3.3 | 74.7 | 0.387 |
3x70mm 2 | 9.3 | 0.10 | 3.4 | 78.6 | 0.268 |
3x95mm 2 | 9.3 | 0.10 | 3.5 | 82.3 | 0.193 |
3x120mm 2 | 9.3 | 0.10 | 3.6 | 85.6 | 0.153 |
3x150mm 2 | 9.3 | 0.10 | 3.7 | 89.3 | 0.124 |
3x185mm 2 | 9.3 | 0.10 | 3.8 | 93.0 | 0.0991 |
3x240mm 2 | 9.3 | 0.10 | 4.0 | 98.7 | 0.0754 |
3x300mm 2 | 9.3 | 0.10 | 4.2 | 103.4 | 0.0601 |
3x400mm 2 | 9.3 | 0.10 | 4.4 | 110.9 | 0.0470 |
Â
We are saleing Touch Screen For Mitsubishi,provides the product information.
Touch screen for Mitsubishi are widely used for medical and industrial equipment, research shows, machinery equipment, industrial control, man-machine interface, industrial automation integrated workstation, POS, CNC etc. we have a lot of Touch Screen for Mitsubishi, standing some of our inventory stock.
Touch screen for Mitsubishi
Touch Screen For Mitsubishi,Touch Screen For Mitsubishi Replacement,Touch Panel For Mitsubishi
GUANGZHOU VICPAS TOUCH TECHNOLOGY CO.,LTD , http://www.touchsuppliers.com